ArcFM Desktop 10.6.1 SP1 ReadMe

« Go Back
Information

ArcFM Desktop 10.6.1 SP1 Release Contents

The ArcFM Desktop installer allows you to upgrade ArcFM as well as the Designer, Conduit Manager, and Redliner extensions. Request a License that corresponds to the current version is required to run these ArcFM Desktop extensions.
All prior patches released on ArcFM Desktop 10.6.1 are automatically included in ArcFM Desktop 10.6.1 SP1.

ArcFM

ArcFM is a powerful collection of tools for managing, modeling, and editing facility and landbase data in an enterprise system.

NOTES

  • For an Oracle database connection in ArcGIS 10.6.1 SP1, use the tns name. For example, use orca.yankees rather than sde:oracle11g:orca.yankees. The longer format leads to inconsistent behavior with regard to login screens. If a stored display has been saved by someone who logged in using the longer format of the login string, connect with only the tns name and save the stored display again.
  • Simple-edge networks require the following configuration for simple edge features:
    • If you are using Feeder Manager 2.0, assign the Feeder Cache Maintenance AU to the On Feature Split event for simple edge features. If there are multiple AUs, the Feeder Cache Maintenance AU should be the last AU assigned. If you are using Feeder Manager 1.0, you do not need this AU.
    • Set Split On Edit to yes for all junction features that connect to simple edges.
  • If you are unable to save stored items in a versioned geodatabase, ArcSDE's MAXBLOBSIZE and MAXBUFSIZE settings may be set too low. Schneider Electric recommends setting these values between 10MB and 20MB. Refer to the ArcFM Solution Online Help for more information on how to change these settings.

ArcFM 10.6.1 SP1 contains the following bug fixes:

  • CLS-69350 - ArcFM Structure Relate has issues if the "structure" is a polygon and the desired related feature is a line.
  • CLS-69355 - Data Source Wizard fails when destination is an SDE connection where user isn't currently logged in.
  • CLS-69590 - Autoupdaters and Model Names tabs are not loading with information.
  • CLS-69976 - An error about maximum length exceeded shows regarding "Feeder Tracing Disabled" is thrown when posting a design with Feeder Sync enabled.
  • CLS-70190 - Structure Relate AU fails when target and destination are structures and the target has a related object.
  • CLS-70457 - Split behavior change in mmAutoUpdaterMode between 10.2.1c SP2 and 10.2.1c SP3.
  • CLS-70575 - Required Fields validation rule is not displaying problem field.
  • CLS-70637 - Phase swap sets wrong "normal position" field on downstream fuse when switching a phase of a two-phase conductor.
  • CLS-70638 - Flow arrows in Find Feeder tool do not cover full extent of feeder.
  • CLS-70782 - ArcFM Gas Valve Isolation Trace issue with Squeeze Offs.
  • CLS-70813 - Unable to localize ArcFM 10.6.1 with en-US culture code with certain forms.
  • CLS-70921 - No warning on abandon for right-click tool.
  • CLS-70970 - Issue with layer extensions and FM2 joins. 

ReadMe Links: 

This service pack includes fixes from all of the following patches:
ArcFM Desktop 10.6.1 ReadMe

ArcFM Solution Mobile

The ArcFM Mobile Solution allows utilities to leverage ArcFM and Designer functionality in the field if the appropriate licenses are in place.

ArcFM Solution Mobile 10.6.1 SP1 contains the following bug fixes:

  • There were no bug fixes for this product.

Conduit Manager and Underground Facilities Manager

Conduit Manager is an integrated set of tools and dialogs to add, annotate, and maintain the underground infrastructure of the utility network system. The Underground Facility Manager allows you to create and manage underground structures that connect the conduit.

Conduit Manager and Underground Facilities Manager 10.6.1 SP1 contain the following bug fixes:

  • There were no bug fixes for this product.

Designer

Designer provides an integrated environment for preparing construction work sketches and job cost estimates. It also provides an automated means to update the baseline corporate GIS database, based on changes to the electrical, gas, and water distribution facilities shown in the work sketch.

Designer 10.6.1 SP1 contains the following bug fixes:

  • CLS-68333 - Designer workflow locks layer editing.
  • CLS-69613 - Field value for a GU node is NOT updated on second attempt in Design tab.
  • CLS-69928 - Period in username prevents populating User_Name column in MM_PX_VERSIONS. 

Designer Express

Designer Express creates a quick construction sketch and cost estimate while relaxing some of the GIS and Accounting principles that can be handled later in the design process.

Designer Express 10.6.1 SP1 contains the following bug fixes:

  • There were no bug fixes for this product.

Network Adapter Classic

Network Adapter Classic provides an interface to export a selected feeder from the geodatabase and import it into a MultiSpeak compliant analysis engine such as Milsoft.

Network Adapter Classic 10.6.1 SP1 contains the following bug fixes:
  • There were no bug fixes for this product.

Network Adapter Standalone

Network Adapter Standalone supports exports of network feeders from an ArcFM geodatabase to MultiSpeak and CIM XMLs, allowing import to Schneider Electric DMS, Windmil engineering analysis tool, and other solutions.

Network Adapter Standalone 10.6.1 SP1 contains the following bug fixes:

  • CLS-68954 - Open points (switch with all phases open) aren't found in the Network Adapter exported XML.

Object Reader for ArcMap

The ArcFM Object Reader provides ArcFM custom geo-objects that allow read-only access to ArcFM data in the geodatabase. Object Reader may be used only with an ArcFM geodatabase and when no other ArcFM Solution Desktop product is installed.
Separate installers are provided for Object Reader to work with ArcGIS Desktop, ArcGIS Server, and for background geoprocessing in a desktop environment. The latter two are 64 bit applications.

Object Reader 10.6.1 SP1 contains the following bug fixes:

  • There were no bug fixes for this product.

Upgrade Information

All upgrade information is available in Upgrade to 10.6.1.

Installation Instructions

PRE-INSTALLATION NOTES

  • Ensure that your hardware and software meet the ArcGIS system requirements.
  • Ensure that your hardware and software meet the ArcFM Supported Versions
  • ArcGIS VBA Compatibility is required by ArcFM.  You can get the ArcGIS VBA Compatibility installer from myEsri under the installation media for either 10.2.1 or 10.3.1 ArcGIS desktop. Note that it is NOT offered in the installation media for Esri’s 10.6 or 10.6.1 releases, but this older version from 10.2.1 or 10.3.1 is still supported and compatible. SE will also make this installer available in the same location as the rest of our 10.6.1 media for easier accessibility.
  • ArcFM Desktop 10.6.1 SP1 products require a complete upgrade to ArcGIS 10.6.1. ArcGIS must be upgraded before you upgrade to 10.6.1 SP1.
  • ArcFM Solution 10.6.1 SP1 requires License Manager version 9.2 or later. You must uninstall all previous versions of License Manager if you wish to use License Manager 10.6.1.
  • When you upgrade to an ArcFM Desktop 10.6.1 SP1 product, you must upgrade all ArcFM Solution products. Mixed versions of ArcFM Solution products are not supported.
  • ArcFM Desktop 10.6.1 SP1 products require that you have 10.6.1 installed before the installation.
  • Anti-Spyware must be disabled before installation to avoid interference with the installation. They may be restarted after installation is complete.

Perform the following steps, in sequence, to install ArcFM Desktop:

  1. Navigate to Downloads.
  2. Double-click the Microsoft installer file for this product.
  3. Follow the instructions to complete the installation.

Sample Data

Sample data is available on the Downloads page.

Known Issue

  • ArcGIS - The ArcFM Data Source Wizard can experience a memory leak when using SQL Server databases. (Esri Bug NIM080967)
  • ArcGIS - ArcFM Map Book Editor Preview crashes ArcMap when the Bing map from ArcGIS Online is in a stored display.
  • ArcGIS - Moving a WMS layer out of a group layer can lead to a crash when switching stored displays.
  • ArcFM - For Oracle clients using Stored Displays that contain joins, you must use direct connect if you want to be able to switch your stored display while already in an open session and have joined layers point to the proper version. TNS-style connections won't work in this case.
  • ArcFM - Labels from underlying features will show through a Map Inset placed on top of them (in terms of drawing order), as per Esri bug BUG-000106546.
  • ArcFM - The Find Feeder tool experiences slowdowns when using Windows Server 2012, as there are delays between entered keystrokes appearing in the UI and doing automatic searching.  These issues haven't been noticed in any other operating system, and are fixed if Windows Server 2016 is used.  Note that the issue is exacerbated by a database with a large number of feeders.  The version of ArcFM code doesn't matter in this case, as the problematic interaction is within the OS framework.
  • ArcFM Desktop & Viewer - A non-exact match search in a numerical field on the ArcFM Display Field Locator will not return Feeder Manager 2 fields because of Esri bug NIM096302.
  • Conduit Manager - Cannot change alignment of cross section annotation. (MM54332)
  • Conduit Manager - Feeder Manager 2.0 fields cannot be configured to show in cross-section annotation.
  • Display Scaling Issues - Certain forms in the ArcFM Solution written in legacy coding languages (Workflow Manager and Session Manager are two examples) may show display scaling issues at high DPI (greater than 100%) settings.  Microsoft has made significant display scaling improvements in the latest .NET framework and in Windows 10 to make it possible to fix these issues, so they are fixed at 10.6.1 and with Windows 10.  Using earlier versions of ArcFM Solution OR using Windows 7 will not contain fixes for these high DPI display issues.
  • Feeder Manager 2 - FM2 joins appear to break annotation expressions. This is because annotation expressions are defined in ArcCatalog, where they are defined to reference a field as LABELTEXT. When you add FM2 joins (or any other join) to your map, the field is prepended with information to make it fully qualified, causing ArcCatalog to not recognize the field. A bug has been filed with Esri.
  • Publishing .MXD's with Feeder Manager 2 - Any customers using FM2 joins that are saved within an MXD or Stored Display will need to remove and re-add the joins before publishing the MXD. Automatic joins will point to the correct FM2 workspace when the map is published and will not have this same issue.
  • File Geodatabase Compression - If you enable the "Compress File Geodatabase" option in Geodatabase Replication, the replica will fail. (Esri Bug)
  • Help - Our context sensitive help opens two tabs in a web browser. (Esri BUG-000096609)
  • Mobile - Using Mobile Sessions and Designs to edit data that causes changes in the Feeder Manager network is not supported. Feeder Manager 2.0 data does not update after replaying mobile sessions, resulting in incorrect Feeder Manager 2.0 data. Applications must be restarted for the changes to appear. 

Documentation

Schneider Electric no longer ships static help files with each software release. All ArcFM Using and Configuration guides are available in the ArcFM Solution Resource Center. The guides are updated on a regular basis. You can view this information before installing the latest release.

Additional Information
ArcFM Desktop 10.6.1 SP1 ReadMe